After reviewing the source documents, I need to make several important corrections to my analysis:
1. Thermal Expansion Coefficient Discrepancy
My analysis used: 120 × 10⁻⁶ /°C (from your thermal report)
Standard PE100 value: 144 × 10⁻⁶ /°C (from PPI technical literature)
Issue: Your project document shows 120 × 10⁻⁶ but doesn't specify units clearly
Impact: This affects thermal stress calculations by ~17%
2. HDPE Yield Strength
My analysis: 22.0 MPa
Correct value: ~24 MPa (3,500 psi) per PPI standards
Impact: Safety factors are actually slightly higher than I calculated
3. Stress Context Clarification
My "combined stress" of 8.75 MPa includes:
Thermal stress: ~2.75 MPa
Pressure stress: ~6.0 MPa
Wind-induced effects: Additional thermal component
Literature thermal stress alone: 1.75-2.07 MPa (typical conditions)
My thermal stress component is higher due to extreme temperature + wind effects
The thermal expansion coefficient discrepancy needs resolution:
Your thermal report states "120 × 10" (units unclear)
Standard PE100 material is 144 × 10⁻⁶ /°C
Question: Is your project using a modified PE100 formulation or is this a documentation error?